Current Location: Home > Product Classification>
Features: *max span 125m *General-purpose fiting size and triggering mode *Compatible to EN418 required with emergency stop *button on the surface cover *the switch works in two direction:tripped when the wire *is pulled or breaking. *The switch can be with indicator light to show the state. *Positive Opening of NC contacts *Conform to EN60947-5-5, *ISO13850, ISOTR 12100, IEC 60947-5-1, EN 418 | Installation dimensions: |
Specifications: Operating Frequency: Mechanical:120ops/min Electrical: 30ops/min Insulation Resistance: >100MΩ @ 500V DC Contact Resistance:<25mW (initial value) Rated Current/Voltage: Ith:10A 600V AC (EN60947-5-1) Electrical Rating: AC15 A600/ DC13 Q300 Dielectric Strength: 1000VAC for 1 min between current carrying parts 2500VAC for 1 min between non-current carrying parts Service Life: Mechanically 10,000,000, Electrically 500,000 Operating Temperature: -25~80℃(-13~176°F) without formation of ice Humidity: < 95%RH Degree of protection: IP67 |